Commerical Electrostatic Precipitator In The Operation We Have To Pay Attention To Matters

Source:

Commerical Electrostatic Precipitator in the operation we have to pay attention to matters
Commerical Electrostatic Precipitator pulse valve rubber diaphragm failure is a common fault, it directly affects the cleaning effect. The device is outside the filter, the bag built-in skeleton, to check the fixed filter bag parts are loose, filter bag tension is appropriate. So the oil mist and water droplets are required, and the oil-water separator must be cleaned regularly to prevent malfunction of the movement mechanism and the bag.
When the Commerical Electrostatic Precipitator to stop running, in addition to the need to thoroughly clean up, but also should pay attention to the following questions:
⑴ bag moisture condensation often occur in the room, which is containing moisture, especially after the combustion of the gas caused by cooling, so the system before cooling, the gas containing the exhaust, completely replaced by dry air, but also It is in the process equipment to stop running, Commerical Electrostatic Precipitator exhaust fan should run for some time before they stop running.
⑵ in the long-term operation, to pay full attention to the fan cleaning, rust and other work to prevent dust and rain into the bearing. Before the cessation of operation, the ash should be ruled out of the ash. The cleaning mechanism and the drive part should be filled with oil.
⑶ in the bag filter to stop running during the regular short-term operation is to ensure the normal operation of the dust removal system maintenance methods.
When the Commerical Electrostatic Precipitator to stop running, in addition to the need to thoroughly clean up, but also should pay attention to the following questions:
⑴ bag moisture condensation often occur in the room, which is containing moisture, especially after the combustion of the gas caused by cooling, so the system before cooling, the gas containing the exhaust, completely replaced by dry air, but also It is in the process equipment to stop running, Commerical Electrostatic Precipitator exhaust fan should run for some time before they stop running.
⑵ Commerical Electrostatic Precipitator in the long-term operation, to pay full attention to the fan cleaning, rust and other work to prevent dust and rain into the bearings. Before the cessation of operation, the ash should be ruled out of the ash. The cleaning mechanism and the drive part should be filled with oil.
⑶ Commerical Electrostatic Precipitator in the bag filter to stop running during the regular short-term operation is to ensure the normal operation of the dust removal system maintenance methods.
Always check the operation of Commerical Electrostatic Precipitator control valves, pulse valves and timers.
Commerical Electrostatic Precipitator pulse valve rubber diaphragm failure is a common fault, it directly affects the cleaning effect. Commerical Electrostatic Precipitator equipment is outside the filter, the bag built-in skeleton, to check the fixed filter bag parts are loose, filter bag tension is appropriate. So the oil mist and water droplets are required, and the oil-water separator must be cleaned regularly to prevent malfunction of the movement mechanism and the bag.
In the daily operation of Commerical Electrostatic Precipitators, due to operating conditions will be some changes, or some failure, will affect the normal operation of the equipment and work performance, to be regularly checked and appropriate adjustments. Attention should be paid to the following questions:
1, running records
Each ventilation and dust removal system must be installed and equipped with the necessary test instruments, in the daily operation must be regularly measured, and accurately recorded, which can be based on the system pressure, inlet and outlet gas temperature, the main motor voltage , Current and other values and changes to determine, and timely discharge failure to ensure its normal operation.
2, safe
Commerical Electrostatic Precipitators should pay special attention to measures to prevent burning, explosion and fire accidents. In the treatment of combustion gases or high temperature gas, there are often incomplete combustion of dust, Mars, burning and explosive gases into the system, some dust has the nature of spontaneous combustion or charged. Should be well considered to take fire, explosion protection measures.
3, fluid resistance
U-type differential pressure meter can be used to determine the operation: If the pressure increases, means that the filter bag appears plug, filter bag with water vapor condensation, cleaning mechanism failure, ash fouling too much so clogging bag, gas flow increased Happening. Box or the division between the leakage phenomenon, the fan speed slow down and so on.